<?xml version="1.0" encoding="UTF-8"?><Articles><Article><id>751</id><JournalTitle>METHOD DEVELOPMENT AND VALIDATION FOR IMPURITY  METHOD OF CINACALCET HYDROCHLORIDE TABLETS  (STABLITY INDICATING) BY HPLC TECHNIQUE</JournalTitle><Abstract>Cinacalcet is a calcimimetic agent and acts on calcium sensing receptor of the parathyroid. Also it increases sensitivity 
of calcium-sensing receptors on parathyroid  glands to extracellular calcium, resulting in decreased serum parathyroid hormone 
(PTH)  and  calcium  concentrations.  The  chemical  name  of  Cinacalcet  Hydrochloride  is  (R) -N-(3-(3-(trifluoromethyl) 
phenyl)propyl)-1-(1-naphthyl)  ethyl  amine  Hydrochloride  and  it  molecular  weight  is  357.4  g/mol  and  molecular  formula, 
C22H22
F
3N. The calcium sensing receptor on the surface of the chief cell of the parathyroid gland is the principal regulator of 
parathyroid  hormone  secretion.  It  acts  by  directly  lowering  parathyroid  hormone  levels  by  increasing  the  sensitivity  of  the 
calcium sensing receptors to activation by extracellular calcium, resulting in the inhibition of PTH secretion. The reduction   in 
PTH is associated with a concomitant decrease in serum calcium levels2. Since, the method for determination of Cinacalcet 
related substances in pharmaceutical products is not described in current pharmacopoeias, the aim of this work was to develop
and  validate  a  precise,  accurate  and  robust  method.  Separation  was  achieved  on  a  RP  C-18  column  (50  x  3.0  mm,  2.5  Âµm 
particle size) along with pre column, column temperature kept at 40Â°C. Gradient method developed to achieve the separation. 
The mobile phase A contains 100% Buffer solution (pH 5.00) and Mobile phase B contains mixture of Acetonitrile and water in 
the ratio of 95:5 V/V, The preparation of buffer was  dissolved in 1.8g of Disodium hydrogen phosphate in 1000 ml of water. 
pH was adjusted to 5.00 with phosphoric acid. Flow rate of 1.0 ml/min. Injection volume 5ÂµL and UV detection wavelength at 
223nm. The method was validated by following ICH guidelines and validation parameters showed that method used as stability 
indicating for determination of related compound of Cinacalcet hydrochloride tablets</Abstract><Email> karikalan11@gmail.com</Email><articletype>Research</articletype><volume>7</volume><issue>5</issue><year>2016</year><keyword>Cinacalcet hydrochloride,HPLC, Method development,Validation</keyword><AUTHORS>M. Karikalan,M.Gnana Ruba Priya,P. Shanmugapandiyan</AUTHORS><afflication>Research Scholar, PRIST University, Tanjore, Tamilnadu, India,Gautham College of Pharmacy, Bangalore, Karnataka, India,Raoâ€™s College of pharmacy, Nellore, Andhra Pradesh, India</afflication></Article></Articles>